RF performance
- Frequency and output power
- Gain and gain flatness
- Harmonics and spurious emissions
- Compression
- VSWR and return loss
- Efficiency and noise
- Modulation, CW and pulsed operation
- Thermal performance
LaserAegis acts as technical lead and Design Authority for RF high-power amplifier systems: band partitioning, power architecture, protection and control design, integration and acceptance. Every unit is built to order, for Australian and international customers.
RF Amplifiers
Band partitioning, power architecture, protection philosophy, and control / monitoring design for RF high-power amplifier systems, delivered across two series — Commodore for defence and operational environments, and Commercial for telecommunications, research and commercial use.
| Standard | Designed and specified to MIL-STD-810F (environmental) and MIL-STD-461D (EMI/EMC) |
| Environment | Defence and operational conditions; environmental limits and qualification requirements depend on the selected product |
| Power range | RF modules: 10–100 W. ARM I: up to 150 W HF / 60 W VHF |
| Frequency range | RF module models: 20 MHz–7.5 GHz. ARM I: 1.6–59.99999 MHz |
| Product lines | Commodore ARM I HF/VHF amplifier; 10–100 W RF amplifier modules in Commodore A and Commodore AB lines |
| Delivery | Engineer-owned, Australian-based. Short lead times, small-batch orders accepted, ITAR-free |
| Best for | Field, vehicle-mounted and operational defence environments |
| Standard | Electrical specifications correspond to the equivalent Commodore RF module models; refer to the selected model |
| Environment | Standard commercial environmental rating |
| Power range | 10–100 W across RF module models |
| Frequency range | 20 MHz–7.5 GHz across frequency-band models |
| Product lines | Commercial RF amplifier modules: 10 W, 25 W, 50 W and 100 W |
| Delivery | Built to order, with the same local, direct-pricing delivery as Commodore |
| Best for | Telecommunications, research, laboratory and commercial systems |
Frequency and power ranges describe the product families, not the coverage of a single unit. RF delivery is tailored to the application, interfaces and agreed acceptance requirements. Specialist manufacturing and test partners support the programme where required, with LaserAegis coordinating technical requirements, integration and acceptance documentation.
Verification scope
RF performance and pre-compliance verification are performed in-house. Formal EMC and environmental qualification is arranged with qualified or accredited facilities where required by the agreed programme scope.
Process, documentation and support apply to every programme. See Engineering & Delivery.
Next step
Tell us the frequency band, output power, supply and environment, and we will recommend the model and series. Replies within one business day.